Wiring Outlets And Lights On Same Circuit
Wiring room lights and outlets to same circuit will definitely help you in increasing the efficiency of your work.
Wiring outlets and lights on same circuit. Yes of course for example desk lamps and other loads can be on the same circuit. Outlets for other equipment within the same bathroom can then work on that same circuit. However there s usually a special circuit for lighting because lighting pulls very little current and so much thinner wire can be used and so a separate lighting. The circuit may be 120 volts 15 amps or 120 volts 20 amps.
The outlets will have to be run first then run a jumper from the black and whit wire to the light switch and then run the wire for the lights fixture and you break the circuit between the jumper that stays hot all the time to the black wire on the light fixture run a white wire to the fixture from the white wire in the switch box and that should give you constant power to the outlets and a way. Of course a kitchen wouldn t be complete without a lighting circuit to brighten the cooking area. At a minimum one 15 amp 120 125 volt dedicated circuit is required to power the ceiling fixtures canister lights under cabinet lights and strip lights if you have them. Bedroom afci circuit for bedrooms this circuit must be afci protected which requires special planning.
Ten lights per curcuit circuit loadingin canada there shall be not more that 12 outlets on any 2 wire branch circuit. It also says that outlets above a counter top should be gfci protected so if you do find that it s ok to have an outlet there use a gfci receptacle because a lighting circuit probably won t already have one. Such outlets shall be considered to be rated at not more that 1 amp per outlet. You cannot have lighting on a circuit with the bathroom receptacle s if that circuit serves receptacles in another bathroom.
Zenfixit says this changes when a 20a circuit powers a single bathroom. However you are permitted to serve all of the outlets receptacles lights etc in one bathroom with a single 20a circuit as long as that circuit does not serve any other loads outside of that single bathroom. With this kind of an illustrative guide you will have the ability to troubleshoot stop and full your projects without difficulty. You want to avoid wiring the fixtures and the receptacles on the same electrical circuit.
One of my wiring books says not to put lights on the 20a small appliance circuits so it would probably apply the other way around too. Requirements for wiring outlets and lighting.