Wire Size For 20 Amp 240 Volt Circuit
4 the nec allows a maximum of a 3 voltage drop on the main branch of a circuit at the farthest outlet of power and 5 total to both feeders and branch circuits to the farthest outlet.
Wire size for 20 amp 240 volt circuit. In your situation however 12ga wire is more than adequate to handle your installation. Nec 240 4 d 3 states that 14 awg must be protected at 15a. The minimum wire size for 40a is 8 awg. The minimum wire size for 50a is 6 awg copper or 4 awg aluminum.
Now size your breaker and wires. A 240 volt plug is the same as a 220 volt plug and it s for a larger appliance that needs more power than most household devices. The minimum wire size for 30a is 10 awg. That will be the size of your circuit and breaker.
The only time you would want to increase the size of the wire to 10ga is if your running more than 100ft to reduce the affects of voltage drop. The wires usually are black or red but one may be white if it is labeled as hot with a black or red stripe near each end. Ground wiring from the electrical source for the home depends on the amount of amps or circuits the home has. For example plugging a heater rated for 20 amps into a 15 amp circuit wired with 14 gauge wire poses a distinct danger.
A typical 240 volt 30 amp circuit includes a double pole circuit breaker which has two terminals for the two hot wires. The calculator allows entry of a voltage drop but caution should be used when doing so to make sure you are calculating the wire sizes in accordance with nec article 210 19 fpn no. Many homes today are built with 200 amp service. Should the circuit breaker fail to operate correctly that heater will draw more current than the wires can safely handle and could heat the wires to the point of melting the insulation around the wires and igniting surrounding materials.
If you re installing this on a 20 ampere circuit with 12 awg wire you ll have to use the screw terminals. So if your running a 20amp circuit at 220v a distance of only 20ft you would want to run this with 12ga wire. 6 is sometimes mandatory for a 200 foot 12 amp run but can be used up to 300 feet on a 12 amp circuit. To install a 20 amp 220 volt outlet you need 12 awg cable with two hot wires and a ground.
Wiring for appliances must be the correct size for the current needed. No neutral wire is required. A 240 volt 3 wire receptacle has three prongs two hot and one ground to accept a 3 prong plug. Choosing the correct wire gauges are important when wiring a home.
You can not use 14 awg anywhere on a circuit that has a 20a breaker. For every extra 50 feet of cable wire up to 8 normally you upgradeto the next size consult you local codes if your unsure about doubleand triple length runs.