Switchgear Drawing Switchboard
The circuit configurations for high and medium voltage switchgear installations are governed by operational considerations.
Switchgear drawing switchboard. When performing acceptance testing verify that the equipment nameplate data matches project drawings and specifications. Low voltage switchboard construction. In this video of tisoft electricaldesign the switchboard dimensiong drawings the way they are produced and the way they can be changed is shown http www. Eaton s drawout molded case pow r line switchboard is the industry s first switchboard solution that offers an innovative draw out mechanism.
Cost effective range of draw out safety. It is used to supply electricity for critical power and critical process applications such as those found in heavy industry manufacturing mining and metals petrochemical pulp and paper utility water treatment as well as datacenter and. Up to 6000a 600 vac main section main devices main section dimensions distribution section and dimensions 10 10 11 12 i line branch. A switchboard with front accessibility and front connected equipment it is an ideal solution where that molded case circuit breakers need to be updated replaced or changed especially those in a.
Switchgear consists of individually mounted and compartmentalized draw out open type circuit breakers. Inspect the physical electrical and mechanical condition of switchgear or switchboard including its anchorage alignment grounding and required clearances. Normally draw out breakers are used and therefore access to the front and rear of the gear is required. To this purpose starting from the single line diagram of a plant it is possible to arrive by selecting the suitable components to the construction of an switchboard and to the relevant declaration of.
Internal arc testing of mv switchgear medium voltage switchboard undergoing preparations for acceptance testing. It can be rated for up to 38 kv and can have current ratings up to 6 000a. Switchgear is the largest of the three. Switchgear is tested to a different ul standard than panelboards and switchboards.
Switchgear compartments and in iec 60298 appendix a as repeated success at kema in 1997 when the. Switchgear switchboards and associated breakers are designed and tested to different standards as shown in the table below resulting in different capabilities and application considerations. Switchboards 12 16 switchboards selection guide description page mds switchboard 400 1200a up to 600 347vac multi distribution switchboard general product description 2 qed 2 switchboard.