How to wire gfci combo switch and outlet gfci switch outlet wiring diagrams.
How to wire multiple gfci outlets. How to wire a gfci and receptacle. In the first diagram the single way switch and light bulb is connected to the load terminal of gfci. This diagram illustrates the wiring for multiple ground fault circuit interrupter receptacles with an unprotected duplex receptacle at the end of the circuit. Then install the 2nd gfci normally.
In this diagram multiple ground fault circuit interrupter receptacles are wired together using pigtails to connect the source. When the code changed to a 20a gfci receptacle for bathrooms yet still allowed multiple bathrooms on that circuit as long as it was only receptacles it boggled my mind. The electrical calc elite is designed to solve many of your common code based electrical calculations like wire sizes voltage drop conduit sizing etc. How many outlets can connect to the first gfci outlet.
The line side of the receptacle is used to power the device while the load side is used to power other devices down the line. Wiring diagram for multiple gfci s. To properly wire gfci or ground fault circuit interrupter receptacles turn off the power to the circuit you re working on and unscrew the cover plate on the outlet box. Click the icons below to get our nec compliant electrical calc elite or electric toolkit available for android and ios.
The load terminals on the gfci are not used and the last receptacle is wired directly to the circuit source. You can add any reasonable number of outlets the concern is to stay within the amperage load of the circuit distance is not a problem as long as your under 200 feet depending on the. If you choose that route you would wire the cable to the 2nd. Gfci receptacles have two sets of contacts line and load.
Two wire cable is run between the gfci s and the hot and neutral wires from the source are spliced to the line terminals at each device. Gfci receptacle in a series with an unprotected outlet. Using the feed through method is there a limit on either the number of downstream receptacles or the distance beyond the gfci outlet. Just connect the cable from the second outlet to the line side of the first gfci or wire nut and pigtail the first gfci.
Any device connected to the load side of a gfci receptacle will be protected by the gfci receptacle. If there is only 1 cable containing 2 3 wires connect the white line wire to the silver or white terminal and connect the black wire to the brass terminal which is the hot terminal. Wiring a gfci outlet with a light switch. In this video i will show you how to wire up a gfi and make a receptacle gfi protected.
I think a dedicated 15a circuit for each bathroom receptacle is far better. Alternatively most gfci outlets come with little stickers to put on the cover plates of downstream protected outlets.