How To Wire A Two Gang Receptacle
In any case the wiring is.
How to wire a two gang receptacle. First the circuit can be direct wired through the receptacle that is the entry cable can be attached to one pair of hot and neutral screw terminals on the receptacle while the exit cable can be attached to the other set of screws. This means there are two receptacles side by side in one electrical box. A 3 gang receptacle box may be the only box on a branch circuit or one of many receptacle boxes. Use wire strippers to strip 1 2 inch of insulation from each individual wire.
The second way wiring them on separate circuits requires two live cables. The neutral wire from the circuit is shared by both sets. Wiring them on the same circuit requires jumper wires. In this wiring the outlet operation has been split into two parts i e.
This is also known as a quad receptacle. There are two basic options for wiring the receptacle to the two cables running through the box. Wiring diagram for dual outlets. In this diagram two duplex receptacle outlets are installed in the same box and wired separately to the source using pigtails spliced to connect the terminals of each one.
Connected the switch output hot to the upper brass terminal and the lower hot terminal should be connected to the switch input hot wire. To attach the wire slightly loosen the screw hook the end of the wire around the screw then tighten the screw again. Box typical inside dimensions are about 2 in. Wiring two outlets in one box.
Attach the bare copper grounding wire to the green screw of your new exterior gfci outlet. Here 3 wire cable is run from a double pole circuit breaker providing an independent 120 volts to two sets of multiple outlets. The steel boxes have the advantage of being self grounding and do not require a grounding wire. The green screw is typically on the bottom of the outlet.
Included are arrangements for 2 receptacles in one box a switch and receptacle outlet in the same box and 2 switches in the same box. The outlet addition methods we show here are based on the most common wiring 14 gauge wire on a 15 amp circuit and an 18 cu in. There are two ways to wire a double gang outlet which is two duplex receptacles together in a double gang outlet box. To do this simply remove the breakaway fin tab between the brass terminals hot as shown in fig.
A 3 gang receptacle box is usually made of metal or acrylonitrile butadiene styrene abs plastic. This wiring is commonly used in a 20 amp kitchen circuit where two appliance feeds are needed such as for a refrigerator and a microwave in the same location. The upper outlet is controlled through the switch while the lower portion is always hot. Although a single receptacle is the most common type you may need to install a dual gang outlet.