Cooper Gfci Outlet Instructions
If the power is not off stop work and call an electrician to complete the installation.
Cooper gfci outlet instructions. 15 125 5 0 5 5 0a usb c charger with tr duplex receptacle bk gy la v w trusbc15 20 125 5 0 5 5 0a usb c charger with tr duplex receptacle bk gy la v w trusbc20 culus listed ul 498 and ul1310. Gfci as an outlet receptacle combo or circuit breaker automatically cuts off the main power supply within millisecond against electric shock. Eaton gfcis are tested to the highest standards and provide. Wiring gfci receptacles with a protected outlet.
Eaton straight blade receptacles cover the full range of residential hospital industrial construction and commercial grades along with special solutions like tamper resistant gfci corrosion resistant severe duty insulated and watertight solutions. Turn off the power at the circuit breaker box. Do not use it with aluminum wire. If the existing electrical box is too small to accommodate a gfci outlet or if the house wiring is aluminum instead of copper you may need to hire a qualified electrician to do this job.
Do not install this gfci receptacle on. This gfci wiring provides protection to a duplex receptacle outlet at the end of the series. If the circuit breakers aren t labeled you can locate the proper switch by plugging a radio into the outlet you plan to change. By connecting the load terminals on the last gfci the wall outlet at the end is protected and can be used just as if it were one of the gfci receptacles.
Nom certified trusbc20 eaton wiring devices 3. Should you install it. E go to step 7b. Do not install the gfci receptacle in an electrical box containing a more than four 4 wires not including the grounding wires.
December 06 2017 cooper electric customer competes in 2017 ideal national championship april 22 2019 cooper electric gives back for earth day december 01 2017 cooper electric adds solar to corporate headquarters. Gfci also known as ground fault circuit interrupter is a protective device which automatically detects the ground faults and leakage current and provides personal protection against electrocution. Installing a gfci receptacle can be more complicated than installing a. For example you can still be shocked if you touch bare wires while standing on a non conducting surface such as a wood floor.
Use this gfci receptacle with copper or copper clad wire. The gfci s features 3. The gfci s features to prevent severe shock or electrocution always turn the power off at the service panel before working with wiring. The receptacle s other outlet to removemake sure the power is off at both outlets.