30a 240v Wire Size
So i guess you could use 10 ga wire with a 60 amp breaker if it was only used for a welder with 50 or less duty cycle.
30a 240v wire size. Common sizes include 14 12 10 8 6 and 2 gauge wire. 30a breaker and 10 gauge wire can be used on 240v ac supply. 4 the nec allows a maximum of a 3 voltage drop on the main branch of a circuit at the farthest outlet of power and 5 total to both feeders and branch circuits to the farthest outlet. Wire is sized by the american wire gauge awg system.
12 gauge wire is used with 20 amperes or less. Wire size is a function of amperage. So 12 gauge wire can be used with 120v 20a or 240v 20a. Go to the next largest wire size if your run is more than 100 feet inside a conduit or ganged with other wires where the heat dissipation may be inhibited.
The calculator allows entry of a voltage drop but caution should be used when doing so to make sure you are calculating the wire sizes in accordance with nec article 210 19 fpn no. 6 is sometimes mandatory for a 200 foot 12 amp run but can be used up to 300 feet on a 12 amp circuit. In addition a circuit breaker rated for. Assumptions to size welder extension cord length.
To calculate a maximum 3 voltage drop with single phase 120 240 volt power i used a power factor of 1 at an ambient temperature of 78 86. Breaker cannot be larger than ampacity of wire except for some loads like more loads. The minimum wire size for 30a is 10 awg. That will be the size of your circuit and breaker.
Also enter one half of the total length of the circuit. Wire gauge refers the physical size of the wire rated with a numerical designation that runs opposite to the diameter of the conductors in other words the smaller the wire gauge number the larger the wire diameter. The receptacles do have to be marked for welder use only. The minimum wire size for 40a is 8 awg.
So 37 5 becomes 40. It s 240 volts amp. Enter the total amperage on the circuit. That said i use 6 ga wire with a 50 amp breaker and either a nema 6 50 or 14 50 receptacle for all of my single phase small to medium size welders and plasma cutters.
For every extra 50 feet of cable wire up to 8 normally you upgradeto the next size consult you local codes if your unsure about doubleand triple length runs. The minimum wire size for 50a is 6 awg copper or 4 awg aluminum. A sample of 120 volts single phase copper wire 144 feet one half of a 288 foot circuit with 10 amps load on it yields a number 10 awg wire size. Under certain circumstances a large wire size may be needed even if your amp requirement does not seem to justify it.